Teflon lip seals provide a wider operating temperature range than the rubber seal (maximum operating temperature of 550º F). Additionally, the Teflon contact results in lower starting torque, therefore these seals can be used in applications where torque sesnsitivity is a consideration. It can cut a groove in the shaft due to the abrasive nature of the tough seal material and the contaminants in the oil.
(2 suppliers)
(1 supplier)
(0 suppliers)
(1 supplier)
(1 supplier)
(8 suppliers)
(17 suppliers)
(5 suppliers)
(2 suppliers)
Teflon Aspirators are used for the extraction or dilution of fluids from chemical tanks. Teflon aspirators include an option for an integral check valve.
(3 suppliers)
(2 suppliers)
(1 supplier)
Dilution drain valve is a mixing valve for diluting solutions while draining a tank. When water pressure is activated, a unique spool valve design moves forward and aspirates the tank dry. When water pressure is deactivated, a PTFE-coated isolated return spring automatically shuts off the valve. It frees up operator to perform other duties while draining tank. It also cools and dilutes solution while draining. These types of valves can be selected for various dilution rates (2:1 and 6:1 standard)
(2 suppliers)
Teflon® Disc Filter is designed to fulfill the special requirements of inline micro filtration for sensitive media.
(1 supplier)
Encapsulated Thermometers is an instrument for measuring temperature of acids, chlorides, sulfates, bleach, solvents, phenols, caustics and peroxides. The thermometer is made more resilient to bumps and jars. It is not unbreakable. However, if the thermometer breaks, the liquid will be retained within the Teflon jacket, therefore stopping contamination wherever the thermometer is being used. Encapsulating the thermometer in Teflon does not change the calibration of the thermometer, but it does increase the lag time. Teflon encapsulated thermometers should not be used in timed tests.
(3 suppliers)
(10 suppliers)
(1 supplier)
Gauge Isolators are manufactured from steel hexagonal bar stock and machined to exact tolerances. Pressure is supplied to the gauge only when requested, by pushing the knob. This prevents gauge failure caused by continuous exposure of the gauge to damaging pressure surges and helps extend the life of the gauge and maintain its accuracy. This design provides simple mounting options and an attractive, compact package.
(4 suppliers)
(10 suppliers)
(2 suppliers)
(3 suppliers)
Metering valves are designed to provide accurate and stable control of flow rates in analytical, instrumentation, and research applications. A variety of connection sizes, body patterns and materials of construction provide considerable application versatility. Precisely tapered valve stem accurately controls flow. It can be panel or in-line mounted. It also has positive handle to stop preventing over tightening. Valve stem threads are not in contact with process fluid. Metering valve dispensing head eliminates uneven clutch application times that result in dot diameter variations. Employing software controlled direct drive technology; head provides the most precise dispensing of multiple dot sizes with one spindle, and multiple dot combinations between spindles. The too less design minimizes cleaning time and simplifies both operation and maintenance. It offers excellent flexibility in dot size and material range, and is the perfect choice for high- ix/high change over.
(8 suppliers)
(3 suppliers)
Teflon Pneumatic Valve is made from a one-piece Teflon body, which provides an optimum anti-corrosion design. These valves use hi-temp upgraded materials. There is no media contact with any elastomers, lube or springs.
(1 supplier)
(1 supplier)
(1 supplier)
Pressure regulator is a valve that automatically cuts off the flow of a liquid or gas at a certain pressure, usually for the purpose of preventing damage to plumbing. They allow sources of water to be used which come at a higher pressure than can be tolerated. Pressure regulators are not only used to stop water, they react to the pressure on their output side, and close when the pressure in the plumbing reaches the designated level. Also when the pressure come down, the valve opens and allows flow until the plumbing pressure goes back up.
(2 suppliers)
(19 suppliers)
(6 suppliers)
(20 suppliers)
(11 suppliers)
(1 supplier)
Teflon Spray Guns deliver the optimum in anti-corrosion protection and long lasting duty wherever harsh chemicals are used. They are available with threaded nozzles or with 1/8 female NPT threaded cap for easy connection to custom spray patterns.
(6 suppliers)
Teflon Stopcocks use a polished joint. Teflon stopcocks do not require expensive lubricant, reduces the risk of contamination and freezing.