Three-fluid heat exchanger is widely used in cryogenics and chemical processes such as air separation systems, purification and liquefaction of hydrogen & ammonia gas synthesis. The dependent performance of the heat exchanger has been expressed in terms of two dimensionless quantities, termed temperature effectiveness. The temperature effectiveness is expressed as functions of five independent dimensionless exchanger variables, three representing operating conditions and two design conditions.